Skip to content

Free tool · Ecuador

Cable vs. busway comparator

In one minute, see what a low-voltage feeder costs to install in Ecuador with copper cable and with busway.

We compare the complete installed cost: conductors, cable tray, lugs, joints, supports, labor and VAT.

1Your installationShow
2Electrical loadShow
System
Neutral
3RunShow
Horizontal elbows
Vertical elbows
Wall or slab penetrations (firestop)
Installation height
4Engineering dataOptional · short circuit, voltage drop, harmonics, overheadShow
Fill in the load and the run to see the result.

Frequently asked questions

Show

Which is cheaper, cable or busway?

It depends on the current, the length and the tap-offs. On high-current feeders (400 A and up) cable needs several conductors in parallel, a wide tray and many lugs; that is where busway usually competes best. On low currents and short runs cable is usually cheaper.

Where do the prices come from?

Cable uses prices published by Ecuadorian retailers (for example Demaco and Kywi). Labor uses the worker-hour cost from a public unit-cost analysis in Ecuador and estimated productivity rates. The sources are listed at the end of the result. If you have other prices or rates, type them in and the calculation updates.

Is the result a quote?

No. It is an illustrative scenario prior to detailed engineering. For a firm figure, request a quote for your project in one click: it already carries your bill of materials.

Why does busway have joints and cable has no splices?

Busway is made in 3 m lengths connected with joints. A continuous cable run needs no splices, so the comparator does not add any.

Which cable does the comparison use?

600 V THHN/THWN-2 copper cable on ladder tray, in a single layer. For 400 A it uses, for example, two 4/0 AWG conductors per phase in parallel, plus neutral and ground. It is a candidate configuration that detailed engineering must confirm.

Glossary

Show
Busway
Copper or aluminum bars inside a metal enclosure that replace cables in feeders and distribution.
AWG / kcmil
Cable sizes. AWG for small sections (14 AWG to 4/0 AWG); kcmil (thousand circular mils) for large sections, e.g. 250 kcmil ≈ 127 mm².
Ampacity
The current a conductor can carry continuously without exceeding its temperature rating.
Joint
The piece that connects two busway lengths and gives the bars electrical continuity.
Labor productivity
Worker-hours a task takes per unit, for example hours per metre of cable pulled.

You can replace the cable prices and the labor productivity rates with your own assumptions. It is an illustrative scenario prior to detailed engineering: for a detailed analysis of your project, turn it into a quote.

Specialist product · GM-Z

Are you looking for medium-voltage busway?

GM-Z is a cast-resin busway built for medium-voltage power: typically the link between generators, transformers and switchgear in power plants and large industrial sites.

It is engineered and quoted project by project. Most commercial and industrial buildings need a low-voltage system such as LVA or GM instead.

Read the GM-Z overview